16 analog inputs/outputs module - MIDAM BAIO1601

Microprocessor controlled module featuring 8 analog inputs with variable measuring range (voltage, resistance, temperature, current loop) and 8 analog outputs 0...10V. The serial line communication is based on Modbus RTU (RS485) protocol. Native modbus map grants seamless integration into variety of PLC/SCADA systems.

  • Microprocessor-controlled module
  • 8 analog inputs/outputs
  • Selectable measuring ranges
  • Modbus RTU (RS485)
  • Integration into SCADA systems
datasheet
+
-
add to inquiry

Function

The BAIO1601 module monitors/controls up to 8 analog inputs and 8 analog outputs. The input signals are processed and multiplexed into a 16 bit A/D converter. Each input is rangeable separately (see Technical data), and inputs can also be used as 0 to 20 mA current measurement inputs if the corresponding DIP switch is activated. The device has factory-set values to ensure the correct default function and allows direct reading and writing of values to the Modbus map, which is available in a separate document. All settings are also stored in the Modbus map directly in the device. If the module is terminating the communication bus, i.e. it is the last in line, a terminating 120 R resistor may be switched on by short-circuiting of the BUS END DIP switch. Three LEDs located inside of the housing enable fast diagnostics – power, communication and system circle indication. The communication circuits are protected against overvoltage and galvanically isolated from other parts of the module. The module is equipped with a watchdog. The module features removable connectors available for all signals as well as for data and power line. This makes its installation and maintenance fast and easy. The module has a DIN rail clip (snap on).

Application

  • Module with 8 analog inputs / 8 analog outputs
  • Analog signal acquisition and control
  • Integration into PLC topology
  • General-purpose use

Addressing

The Modbus address can be set in two ways. Using DIP switches, they increase their bit weight from right to left, see image with example where address of 98 is set by activation of switches 2, 3, and 7 with bit weight of 64, 32, and 2 respectively. Valid settable range is 1 to 254. Address 0 (all switches OFF) means that the address is set as entered in the Modbus table. Address 255 (all switches ON) brings the module to INIT (factory settings) mode, where Modbus address is 1 and communication parameters are set to 9600, 8, N, 1. Software addressing is available using appropriate software tool delivered by the device manufacturer. The software addressing feature is active provided the hardware addressing switch is set to 0 only. All changes apply after the module is switched off and on again.

Configuration

The device is configured using the manufacturer’s tool or with a standard modbus tool, modifying the appropriate registers. The different operation modes and user access can be configured in this way. Modifications to the controller configuration can be made afterwards without the need for any special tools.

PLC system integration

The module can be integrated via the Modbus RTU (RS485).